Descripción

Amplifier Unit
Model EG-520
Type DC
Sensitivity adjustment 15-turn trimmer
Function Operation mode N.O./N.C. (switch-selectable)
External synchronization ?
Output Control output 1 (NPN) 200 mA max. (40 V max.) Residual voltage: 1 V max.*1
Control output 2 ?
Disconnection alarm output(NPN)
Response time (Relay contact) 1 ms
?
OFF-delay time
Temperature characteristics 0.08%/°C*2
Rating Power voltage 11 to 30 VDC, Ripple (P-P) 10 % or less
Power consumption 100 mA mAx.
Environmental resistance Ambient temperature 0 to +50 °C
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Weight Approx. 110 g