Descripción

Fibre Amplifier, M8 Connector Type, Main Unit
Model FS-N41C*1
Type M8 Connector*2
Main unit/expansion unit Main unit
Number of control outputs 2*3
Number of external inputs 1*3
Light source LED Transmitter side: Red, four-element LED (wavelength 660 nm)
Response time 23 µs (S-HSPD*4)/50 µs (HSPD*5) / 250 µs (FINE) / 500 µs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA) / 64 ms (TERA)
Control output Open-collector, 30 V or less 100 mA or less per output, 100 mA or less total for 2 outputs (when used as a solitary unit) / 20 mA or less (when used as an expansion unit) Residual voltage NPN 1.4 V or less (output current 10 mA or less) / 2 V or less (output current 10 to 100 mA) PNP 1.6 V or less (output current 10 mA or less) / 2.2 V or less (output current 10 to 100 mA)
External input Input time 2 ms (ON) / 20 ms (OFF) or longer*6
Protection circuit Protection against reverse power connection, output overcurrent, output surge, and reverse output connection
Mutual interference prevention S-HSPD/HSPD 0 units, FINE 4 units, TURBO/SUPER/ULTRA/MEGA/TERA 8 units (The mutual interference prevention values are twice those shown here when Double is set.)
Power supply Power voltage 10 to 30 VDC (including 10% ripple (P-P) or less) , class 2 or LPS*7
Current consumption During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V) ECO ON: 840 mW or less (33 mA or less at 24 V/60 mA or less at 12 V) ECO FULL: 750 mW or less (30 mA or less at 24 V/52 mA or less at 12 V)*8
Environmental resistance Ambient light Incandescent lamp: 20,000 lux or less, sunlight: 30,000 lux or less
Operating ambient temperature -20 °C to +55 °C (no freezing)*9
Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each for X, Y, and Z axes
Shock resistance 500 m/s2 , 3 times each for X, Y, and Z axes
Case material Main unit and cover: polycarbonate
Weight Approx. 25 g
*1 IO-Link Specification V.1.1/COM2 (38.4 kbps) is supported. *2 Ensure the cable length is 30 m or less for the M8 connector type. Ensure the cable length is 20 meters or less when connecting by way of IO-Link. *3 Output 2 and the external input are selectable. *4 Restrictions when S-HSPD is selected Output 2 of dual output types is fixed to OFF. IO-Link communication cannot be used. Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode. Output timer, Limit Detection, and Display Gain cannot be used. FULL cannot be selected for the ECO function. *5 Restrictions when HSPD is selected Display Gain cannot be used. *6 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected. *7 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher. *8 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max. *9 When expanded by 1 to 2 units: -20 °C to +55 °C. When expanded by 3 to 10 units: -20 °C to +50 °C. When expanded by 11 to 16 units: -20 °C to +45 °C. When using 2 outputs, 1 unit is counted as 2 units. The prescribed values for the ambient temperature assume that the sensor amplifier has been mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space.
''