Descripción

Sensor heads
Model IL-2000*1
Reference distance 2000 mm
Measurement range 1000 to 3500 mm
Light source Type Red semiconductor laser, wavelength: 655 nm (visible light)
Laser class Class 2 laser product (FDA (CDRH) Part 1040.10,*2 IEC 60825-1)
Output 560 µW
Spot diameter (at standard distance) Approx. 1,400 x 7,000 µm
Linearity ±0.16% of F.S. (When used under 1000 to 3500 mm)*3
Repeatability 100 µm*4
Sampling rate 0.33/1/2/5 ms (Variable to 4 levels)
Operation status indicators Laser emission warning indicator: green LED, Analog range indicator: orange LED, Reference distance indicator: red/green LED
Temperature characteristics 0.016% of F.S./°C*5
Environmental resistance Enclosure rating IP67
Pollution degree 3
Ambient light Incandescent lamp: 10,000 lux*6
Ambient temperature -10 to +50 °C (No condensation or freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Material Housing material: PBT, Metal: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC
Weight Approx. 350 g
*1 Amplifiers purchased before August 8th, 2012 cannot be used. *2 The laser classification is implemented based on IEC 60825-1 in accordance with the requirements of FDA (CDRH) Laser Notice No. 50. *3 Value when measuring the KEYENCE standard target (white diffuse object). F.S. for each model is as follows: IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm *4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 16. For the IL-300/IL-600, the sampling rate is 2 ms. *5 F.S. for each model is as follows: IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm *6 Value when the sampling rate is set to 2 ms or 5 ms.
''