Descripción

Sensor heads
Model IL-300
Reference distance 300 mm
Measurement range 160 to 450 mm
Light source Type Red semiconductor laser, wavelength: 655 nm (visible light)
Laser class Class 2 (FDA (CDRH) Part1040.10)*1 Class 2 (IEC 60825-1)
Output 560 µW
Spot diameter (at standard distance) Approx. o0.5 mm
Linearity ±0.25% of F.S. (160 mm to 440 mm)*2*3
Repeatability 30 µm*4
Sampling rate 0.33/1/2/5 ms (4 levels available)
Operation status indicators Laser emission warning indicator: Green LED, Analogue range indicator: Orange LED, Reference distance indicator: Red/Green LED
Temperature characteristics 0.08% of F.S./°C*3
Environmental resistance Enclosure rating IP67
Pollution degree 3
Ambient light Incandescent lamp: 5,000 lux*5
Ambient temperature -10 to +50 °C (No condensation or freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Material Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC
Weight Approx. 135 g
*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice No.50. *2 Value when measuring the KEYENCE standard target (white diffuse object). *3 F.S. of each model is as follows. IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm *4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms. *5 Value when the sampling rate is set to 2 ms or 5 ms.
''