Descripción

Detection distance 5 m, Cable with connector M12, Laser Class 2
Model LR-TB5000C
Type Cable with connector M12
Detectable distance 60 to 5000 mm*1
Spot diameter Variable (use a spot diameter of 40 mm or less)
Response time 1 ms/10 ms/25 ms/100 ms/1000 ms selectable
Light source Type Red laser (660 nm)
Laser class Class 2 laser product (IEC60825-1,FDA (CDRH) Part1040.10*2)
Mutual interference prevention function 4 units (when using the interference prevention function)
Timer OFF/OFF delay/ON delay/One-shot
Power voltage 20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS
Current consumption 50 mA or less (without load)*3
I/O Control output NPN open collector/PNP open collector selectable 30 VDC or less, 50 mA or less, residual voltage: 2 V or less, N.O./N.C. selectable *4*5
External input Switchable between transmission OFF, teaching, and reference surface update Short-circuit current: 1 mA or less for both NPN and PNP For the applied voltage, see the wiring diagrams (pages 2 and 3 in the instruction manual). For the input times, see the time charts (page 4 in the instruction manual).*3
Analogue output Current output/Voltage output selectable Current output: 4 to 20 mA with a max. load resistance of 500 ? Voltage output: 0 to 10 V with an external load resistance of 5 k? or more *4*5
Protection circuit Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge
Environmental resistance Enclosure rating IP65/IP67 (IEC60529)
Ambient light Incandescent lamp/Sunlight: 10,0000 lux or less
Ambient temperature -20 to +55 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 1,000 m/s2, 6 times in each of the X, Y, and Z directions
Material Case: Zinc die cast (Nickel chrome plating), Indicator cover and buttons: PES, Lens cover and display: PMMA (scratch-resistant coating specifications), Cable bushing: PBT, Cable: PVC, M12 connector: TPE, PBT, Nickel-plated brass
Accompanying items Instruction manual, Laser warning and explanation labels
Weight Approx. 160 g
*1 The range for displayable distance is from 50 to 5200. *2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *3 150 mA or less (with load) *4 You can select the I/O from the following combinations. Control output ? 2, control output + external input Control output + analogue output (LR-TB5000/TB5000C/TB5000CL only), External input + analogue output (LR-TB5000/TB5000C/TB5000CL only) (For details on the setting method, see the instruction manual.) *5 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com). If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
''