Descripción

Rectangular w/ M8 connector type, 500 mm
Model LR-ZH500C3P*1*2
Type U.C.D. Function Distance based laser sensor
Shape Rectangular
Output PNP
Cable connection M8 connector, 3-pin
Detectable distance 35 to 500 mm (465 to 0)*3
Standard detectable deviation 35 to 180 mm: 9 mm 180 to 300 mm: 25 mm 300 to 400 mm: 40 mm 400 to 500 mm: 50 mm
Display resolution 1 to 5 (1 to 5 mm)
Spot diameter Approx. o3 mm
Response time 1.5 ms / 10 ms / 50 ms selectable
Light source Type Red laser (660 nm)
Laser class Class 2 laser product (IEC60825-1) Class II Laser product (FDA (CDRH) Part1040.10)
Function Indicator 3-digit 7-segment display (white), output indicator (yellow), DATUM indicator (orange), 1 spot indicator (green)
Timer OFF/ON delay/OFF delay/One-shot
Rating Power voltage 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS
Power consumption 450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)
Specifications Control output PNP Open collector, Applied voltage 30 VDC or less, Control current 100 mA or less, Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA
Protection circuit Protection against reverse power connection, output overcurrent, output surge, reverse output connection
Output operation Light-ON / Dark-ON selectable
Environmental resistance Enclosure rating IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*4, Diversey*4
Insulation resistance 20 M? or more (500 VDC)
Ambient light Incandescent lamp: 10,000 lux or less Sunlight: 20,000 lux or less at 250 mm*5 Incandescent lamp: 2,000 lux or less Sunlight: 4,000 lux or less at 500 mm*5
Ambient temperature -10 to +50 °C (No freezing)
Storage temperature -25 to +75 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Withstand voltage 1,000 VAC, 50/60 Hz, 1 min
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 1,000 m/s2, 6 times in each of the X, Y, and Z directions
Material Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, Packing/Connector ring: FKM
Accessories Instruction Manual, FDA warning/certification/identification label, Laser warning/explanation labels
Weight Approx. 55 g
*1 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website. If using the product in an environment in which downloading files over the internet is not possible, contact your nearest KEYENCE office. *2 M8 connector (3-pin) type does not include the external input function. *3 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds '-99', '-FF' is displayed. *4 Have passed resistance tests with cleaning agents from multiple manufactures. *5 When the response time is 10 ms
''