Descripción

Amplifier Unit, Expansion Unit, PNP
Model LV-12SAP
Type Expansion unit (1 line)
Main unit/Expansion unit
Applicable model LV-S61/S41/S41L/S31/S71/S72
Control output PNP open-collector ? 2 channels, 30 VDC maximum, 100 mA or less per output
Response time ExceptLV-S31 ULTRA 4 ms
SUPER 2 ms
TURBO 500 µs
FINE 250 µs
HSP 80 µs
LV-S31standard mode 500 µs
LV-S31standard mode SPED2 2 ms
SPED3 8 ms
SPED4 32 ms
LV-S31High-speed mode 250 µs
Control input Light emission stop input, external calibration, set value bank selection input, or received light intensity shift input
Number of interference prevention units ULTRA 4
SUPER
TURBO 2
FINE
HSP 0
Unit expansion Up to 16 units (17 units total including the main unit)*1
Rating Power voltage 12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*2
Power consumption Normal 1.5 W or less (62.5 mA or less at 24 V)
Ratings Eco-Half Eco-All 1.35 W or less (57.3 mA or less at 24 V)
Environmental resistance Ambient temperature -10 to +55 °C (No freezing)*3
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis
Material Main unit Main body, cover: Polycarbonate
Weight Approx. 80 g (including 2 m cable)
*1 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is *2 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % max. *3 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C, 3 to 10 units connected: -10 to +50 °C, 11 to 16 units connected: -10 to +45 °C
''